Facets (new session)
Description
Metadata
Settings
owl:sameAs
Inference Rule:
b3s
b3sifp
dbprdf-label
facets
http://dbpedia.org/resource/inference/rules/dbpedia#
http://dbpedia.org/resource/inference/rules/opencyc#
http://dbpedia.org/resource/inference/rules/umbel#
http://dbpedia.org/resource/inference/rules/yago#
http://dbpedia.org/schema/property_rules#
http://www.ontologyportal.org/inference/rules/SUMO#
http://www.ontologyportal.org/inference/rules/WordNet#
http://www.w3.org/2002/07/owl#
ldp
oplweb
skos-trans
virtrdf-label
None
About:
When Resources Are Scarce - Feasibility of Emergency Ventilation of Two Patients With One Ventilator
Goto
Sponge
NotDistinct
Permalink
An Entity of Type :
schema:ScholarlyArticle
, within Data Space :
covidontheweb.inria.fr
associated with source
document(s)
Type:
Academic Article
research paper
schema:ScholarlyArticle
New Facet based on Instances of this Class
Attributes
Values
type
Academic Article
research paper
schema:ScholarlyArticle
isDefinedBy
Covid-on-the-Web dataset
title
When Resources Are Scarce - Feasibility of Emergency Ventilation of Two Patients With One Ventilator
Creator
Beck, Jürgen
Bürkle, Hartmut
Reinacher, Peter
Schick, Martin
Schlaepfer, Thomas
»more»
source
MedRxiv
abstract
A potential shortage of intensive care ventilators has led to the idea to ventilate more than one patient with a single ventilator. Besides other problems, this is associated with the lack of knowledge concerning distribution of tidal volume and the patients' individual respiratory system mechanics. In this study we used two simple hand-manufactured adaptors to connect physical models of two adult respiratory systems to one ventilator. The artificial lungs were ventilated in the pressure-controlled mode and we investigated if disconnecting one lung from the ventilation circuit for several breaths would allow to determine reliably the other lung's tidal volume and compliance. Compliances and volumes were measured both with the ventilator and external sensors corresponded well. However, tidal volumes measured via the ventilator were smaller compared to the tidal volumes measured via the external sensors with an absolute error of 5.3 +/- 2.5%. The tidal volumes of the individual artificial lungs were distributed in proportion to the compliances and did not differ relevantly when both artificial lungs were connected to when one was disconnected. We conclude that in case of emergency, ventilation of two patients with one ventilator requires two simple hand-crafted tubes as adaptors and available standard breathing circuit components. In such a setting, respiratory system mechanics and tidal volume of each individual patient can be reliably measured during short term clamping of the tracheal tube of the respective other patient.
has issue date
2020-04-15
(
xsd:dateTime
)
bibo:doi
10.1101/2020.04.10.20060525
has license
medrxiv
sha1sum (hex)
731f24ad8c8e08942ce33da5cc3dbecd393eb4f7
schema:url
https://doi.org/10.1101/2020.04.10.20060525
resource representing a document's title
When Resources Are Scarce - Feasibility of Emergency Ventilation of Two Patients With One Ventilator
resource representing a document's body
covid:731f24ad8c8e08942ce33da5cc3dbecd393eb4f7#body_text
is
schema:about
of
named entity 'individual'
named entity 'PATIENTS'
named entity 'ASSOCIATED WITH'
named entity 'IDEA'
named entity 'SINGLE'
»more»
◂◂ First
◂ Prev
Next ▸
Last ▸▸
Page 1 of 2
Go
Faceted Search & Find service v1.13.91 as of Mar 24 2020
Alternative Linked Data Documents:
Sponger
|
ODE
Content Formats:
RDF
ODATA
Microdata
About
OpenLink Virtuoso
version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2025 OpenLink Software